Home > Tags > 280 Degree Fusible Link Smoke Damper

280 Degree Fusible Link Smoke Damper

A 280-degree fusible link smoke damper is a passive fire and smoke control device designed to automatically close when exposed to high temperatures. It is typically installed in heating, ventilation, and air conditioning (HVAC) ductwork that penetrates fire-rated walls, floors, or partitions. Its main purpose is to limit the spread of smoke and hot gases through ducts during a fire, helping to protect escape routes and compartmentalize the building.The key component of this type of damper is the fusible link rated at 280°F (approximately 138°C). Under normal conditions, the damper blades remain in the open position, allowing air to flow freely through the duct system. When the ambient temperature in the duct or surrounding area reaches 280°F, the fusible link is designed to melt or separate. This action releases the damper’s spring-loaded or gravity-operated mechanism, causing the blades to close and form a barrier to smoke and heat.A 280-degree temperature rating is selected for applications where higher ambient temperatures may be present in normal operation, or where additional time is required before closure is triggered. This is especially important in certain industrial, commercial, or mechanical room environments, where lower-temperature links might cause nuisance closures. The higher temperature setting ensures the damper activates specifically in fire conditions, rather than in response to routine temperature fluctuations.Smoke dampers are generally constructed from galvanized or stainless steel, with blades and frames designed for durability, air tightness, and smooth operation. The 280-degree fusible link model is typically tested and rated for both fire resistance and leakage performance in accordance with relevant building codes and standards. Proper installation is critical: the damper must be correctly oriented in the duct, adequately supported, and accessible for inspection and maintenance.Maintenance involves periodic visual inspection of the damper blades, frame, and linkage, as well as functional testing where possible. The fusible link should be checked for corrosion, paint, or debris that could interfere with its operation. Any damaged or questionable fusible link must be replaced with a link of the same temperature rating and design to preserve the intended performance.In a complete life safety system, 280-degree fusible link smoke dampers work alongside fire dampers, combination fire/smoke dampers, smoke detectors, fire alarms, and control panels. By closing at a defined temperature threshold, they contribute to smoke control strategies designed to maintain tenable conditions in escape routes and protected areas, support firefighting operations, and limit property damage. Their simple, mechanical actuation makes them reliable components in both new construction and retrofit projects where effective smoke containment is required.

Products

Category:
view:
  • Normally Open 280 Degree Smoke Fire Damper for Mechanical Exhaust Systems

    Normally Open 280 Degree Smoke Fire Damper for Mechanical Exhaust Systems

    Category: Dampers
    Browse number: 7
    Number:
    Release time: 2026-02-10 11:08:37
    The Smoke Fire Damper is a dual-function fire protection component installed in building mechanical smoke exhaust systems, combining active smoke exhaust capability with automatic high-temperature fire containment in a single unit. Normally open during both daily ventilation and the active smoke exhaust phase of a fire event, it allows smoke to be drawn out of the fire zone by the exhaust fan system, protecting evacuation routes and enabling firefighting operations. When exhaust duct temperatures reach 280°C — the threshold at which continued exhaust operation would risk spreading fire through the ductwork — the integrated fusible link element triggers automatic blade closure, simultaneously sending a linkage signal to stop the smoke exhaust fan and prevent flames from traveling further through the duct system. The Smoke Fire Damper supports three control modes: thermal automatic closure via the 280 Degree Fusible Link Smoke Damper mechanism, electric remote closure via DC24V fire alarm linkage, and manual on-site closure. Signal feedback output to the fire control room is standard. Manufactured from galvanized steel or stainless steel with fire-rated sealing components, the unit complies with GB 15930-2024 national standards and is widely specified for high-rise buildings, shopping centers, underground car parks, hospitals, industrial facilities, and public assembly buildings across Southeast Asia and global markets.

News

Category:
No search results found!

Case

Category:
No search results found!

Video

Category:
No search results found!

Download

Category:
No search results found!

Job

Category:
No search results found!

Featured Products

No search results found!

About Us

Dezhou Pengkai Air Conditioning Equipment Co., Ltd. is a professional HVAC manufacturer based in Shandong Province, integrating R&D, production, sales, and after-sales service. Products include fans, dampers, fan coil units, cooling towers, water tanks, and related systems. ISO 9001 certified and CE compliant, Pengkai serves customers across Southeast Asia, the Middle East, Europe, and Africa, offering OEM and ODM services with efficient global delivery.

Contact Us

Luqiantun Tengzhuang Industrial Park, Dezhou City, Shandong Province

pengkaihvac@gmail.com

+86 538 6340005

WhatsApp;2132469498

Follow Us

Copyright ©  2026 Dezhou Pengkai Air Conditioning Equipment Co., Ltd  All rights reserved

Sitemap

This website uses cookies to ensure you get the best experience on our website.

Accept Reject